5 operational recommendations – Flowserve ISC Series User Manual

Page 14

Advertising
background image

14

5 Operational Recommendations

5.1 Do not exceed corrosion limits. The ISC is designed to resist

corrosion by most chemicals. However, do not expose the ISC

materials of construction to products outside of their corrosion limits.

The ISC assembly drawing lists the materials of construction.

Consult Flowserve for chemical resistance recommendations.

5.2 Do not exceed the recommended maximum pressure and

speed limits shown in the ISC brochure.

5.3 Do not exceed the temperature limits of the ISC. The materials of

construction are listed on the ISC assembly drawing. For dual seals

using supply tanks with cooling coils, turn on cooling water to the

supply tank before start-up.

5.4 Do not start up or run the ISC dry. Buffer/barrier fluid must be in

the seal cavity for dual seals at all times during pump operation.

Process fluid must be in the pump volute at all times during single

seal operation.

Advertising