Hypregun-Plus 5Q sealant delivery is affected by the loading

pressure, ambient temperature, and the viscocity of the sealant

being pumped. The chart below provides laboratory test data

which illustrates sealant delivery under common operating

conditions. Also provided in the chart is comparison data

illustrating the improved performance of the Hypregun-Plus 5Q

over the Hypregun.

The Hypregun-Plus 5Q has also been tested for durability.

After 100 hours of continuous operation at atmospheric pressure

the Hypregun-Plus 5Q performed flawlessly.

Injecting sealant at ambient temperatures much lower than

that represented by the chart is accomplished by using the

practical approach of keeping the gun and sealant in a warm

place and only exposing them to extremely cold conditions

during valve injection.

Sealant Output Test Data

Hypregun-Plus 5Q

Hypregun

oz./min.

13.84

3.34

Strokes/min.

175.00

92.00

oz. Per Stroke

.08*

.04

Test Sealant

1033 bulk

Temperature

70°F.

Air Supply Pressure

100 psi

* 13 strokes per ounce