Troubleshooting Guide

Problem: The air motor (1) is operating but sealant is not

being dispensed.

Cause 1: Air is trapped within the down tube assembly.

Solution 1: Bleed the system as described in sections 7 through 9

on page 12 of this manual.

Cause : Loose down tube assembly.

Solution : Tighten as needed.

Cause : Primer rod and foot valve assembly (45) is worn or pitted.

Solution : Rebuild the assembly using down tube kit 1900016.

Problem: The sealant can is difficult to remove from the follower.

Cause: Dimensional tolerances of the can and follower are restricting

can movement.

Solution: Remove air supply and attach to nipple (57, Section B-B).

Slowly open the relief valve (64) 1/4 turn to allow air to enter

the can. The can will be forced from the follower.

Problem: The air motor (1) does not operate when the throttle

valve (3) is opened.

Cause 1: The movement of internal parts of the air motor is restricted

due to debris being entrapped in the motor.

Solution 1: Replace the air motor.

Cause : The thin wall of the air motor cyclinder has been

dented thus restricting movement of internal parts.

Solution : Replace the air motor.

Cause : The nylon air tube (5) is cracked.

Solution : Replace the nylon air tube.

Cause 4: Air supply pressure to gun is too low.

Solution 4: Check output pressure of the air supply.

Cause 5: Air passages to air motor are blocked.

Solution 5: Clean air passages of obstructions.

Cause : Obstruction in down tube assembly.

Solution : Disassemble the down tube assembly (36), clean,

and reassemble.

Cause : Down tube assembly not assembled to proper length.

Solution : Disassemble down tube assembly and assemble to

proper length by aligning roll pins (38 - two locations).

Cause : Metal air tube (91) on the air motor is crushed.

Solution : Remove the metal air tube assembly and replace.

Problem: The air motor will operate only 1/2 stroke.

Cause 1: The air motor slide valve is worn or damaged.

Solution 1: Install new air motor repair kit 47510.

Cause : Obstruction in down tube assembly (36).

Solution : Disassemble the down tube assembly, clean,

and reassemble.

Problem: The follower movement into the can is restricted.

Cause 1: Can too small.

Solution 1: Use Nordstrom five-quart (4.7 litre) can with welded seam.

Cause : Follower wiper (35) is too large.

Solution : Install new wiper.

Problem: As follower enters can, sealant bypasses the follower O-ring.

Cause 1: Follower wiper (35) is too small.

Solution 1: Install new wiper.

Cause : Can is too large or bent.

Solution : Use Nordstrom five-quart (4.7 litre) can with welded seam.

Cause : Can swells or distorts.

Solution : Install can shield (72).

Problem: The follower (34) will not go completely to the bottom of

the can.

Cause: The bottom of the cylinders (19) contain water.

Solution: Remove air pressure from the unit, unscrew the cylinders

and drain the water. Dry the cylinders and check for oxidation

before reassembly.

Problem: The air motor (1) operates slowly even with 125 psi

(8.6 bar) air supply pressure.

Cause: Air flow is being restricted to the air motor.

Solution: Replace the nylon air tube (5) or the metal air tube (91).

Problem: Yoke will not move.

Cause 1: Nipple (7) blocked.

Solution 1: Remove obstruction from air passages making sure the air

supply is of a clean source.

Cause : The ram needle valve (8) is closed.

Solution : Slowly open the ram needle valve. Once the follower has made

contact with the can, open the ram needle valve to 2-1/2 turns.

Cause : The ram needle valve (8) is blocked.

Solution : Remove obstruction from the ram needle valve passage.

Cause 4: Air passages in the yoke (12) are blocked.

Solution 4: Clear obstruction from air passages or replace the yoke.

Problem: Yoke will not raise or lower evenly.

Cause 1: Cylinder (19) is dry of lubrication.

Solution 1: Introduce a light air tool oil into the air system. Use an oil

which is compatible with rubber to prevent swelling of the

piston packing.

Cause : Piston rods (22) are bent or scored.

Solution : Replace damaged piston rod(s).

Cause : Piston packing (26) has swollen and is too tight

in cylinder (19).

Solution : Replace the piston packing.

Cause 4: Piston packing (26) is too tight in cylinder (19) due

to cylinder distortion.

Solution 4: Replace the cylinder.

Cause 5: Air passages of the base (18) are blocked.

Solution 5: Clean air passages using a stiff wire or replace the base.

Problem: The yoke will not raise when the air supply is connected to

the nipple (57).

Cause: The restrictor ell assembly (30) air passage is blocked.

Solution: Clean the air passage using a small, stiff wire or redrill

the air passage hole using a #55 wire gauge drill bit.

These troubleshooting tips are provided as a means of assisting the consumer in overcoming difficulties encountered with prolonged use of a

Hypregun-Plus 5Q. Part numbers in parentheses denote illustration numbers as listed on pages 5 and 6 of this brochure.

WARNING: Never attempt to repair a Hypregun-Plus 5Q without first disconnecting the air supply.