Lower arm, P4 p5/ep5 – Flowserve PMV P4 User Manual

Page 21

Advertising
background image

21

Lower arm

Once the front cover is removed, the lower arm can be easily accessed.

Remove the indicator, feedback spring and the cam.

Loosen screw 2 and remove twist stop 1.

Remove screw 3, lower arm 4, rod 5 and spring 6.

Check rod and lower arm for wear, replace if necessary. Clean the rod and install it in the
lower arm. The lower arm should move easily and smoothly.

Install the lower arm and rod assembly into the positioner housing, making sure that the
spring 6 is attached properly to the lower arm and positioner housing.

Secure the lower arm and rod assembly with the screw 3.

Check again that the lower arm moves smoothly.

Apply a small amount of grease on the small tongue on the lower arm, then install and secure
the twist stop.

Install cam, feedback spring, indicator and front cover.

6

2 1 5

4

3

O rings

4

3

2 1 5

6

P4

P5/EP5

Advertising
This manual is related to the following products: