1 trouble shooting, Defect no. possible causes remedy – Flowserve IOM Control Valves User Manual

Page 23

Advertising
background image



EN

4.1 Trouble shooting

Defect

No. Possible causes

Remedy

Spindle does not move

1.1

1.2

1.3

1.4

1.5

1.6

• no aux. energy supply (pneumatic

air or electrical power) to actuator

and

accessories

(solenoid

valve, filter-reducing station,

positioner, limit switch and special

accessories)

• the fitted accessories do not work

• the pneumatic actuator is

defective

• the electrical actuator is defective

• excessive tightening of the stuffing

box packing

• valve trim worn, stuck

• pneumatic actuators: check supply line for leaks

check pressure (usually 6 bar)

• electrical actuators: check power supply

(connections, circuit breakers, voltage)

• see maintenance and operating instructions of

accessories manufacturer

• contact customer services department or

contract partner

• see maintenance and operating instructions of

actuator manufacturer

• loosen stuffing box packing nuts until valve

operates properly

Caution:

make sure there are no leaks!

• contact customer services department or

contract partner

Jolting spindle movement

2.1

2.2

2.3

• the electrical actuator is defective

• damaged spindle

• actuator not powerful enough

• clean spindle with suitable cleaning agent

• contact customer services department or

contract partner

• compare actuator specs on the rating plate

with operation specifications of the facility

- if incompatible, contact customer services

department or contract partner

Spindle travel

less than full stroke

(0 to 100% stroke)

or flow rate is too low

3.1

3.2

3.3

3.4

3.5

• air supply pressure too low

• pneumatic actuators: bad hand

wheel position (hand wheel

emergency operation)

• electrical actuators: limit switch

misadjusted

• badly adjusted or defective

positioner

• foreign particles in valve seat,

damaged trim

• provide air at the pressure stated on the rating

plate

• move hand wheel to limit position

• readjust limit switch to actuator manufacturer‘s

specification

• readjust positioner to positioner manufacturer‘s

specifications

• contact customer services department or

contract partner

Advertising