1 specifications – Flowserve 3400IQ Digital Positioner User Manual

Page 10

Advertising
background image

Logix 3400IQ Digital Positioner FCD LGENIM3401-00 – 06/06

10

4.1

Specifications

Table I: Electrical Specifications

Power Supply

Two-wire, 9-32 VDC
FF compatible

IS

Fisco compliant

Communications

FF Protocol ITK 4.6x

Operating Current

23 mA

Maximum Voltage

36.0 VDC

Table II: Environmental Conditions

Operating Temperature Range

Standard

-40° to 176°F

(-40° to 80°C)

Transport and Storage

Temperature Range

-40° to 176°F (-40° to 80°C)

Operating Humidity

0 - 100% non-condensing

Note: The air supply must conform to ISA Standard ISA 7.0.01 (a dew point at least 18

degrees Fahrenheit below ambient temperature, particle size below five microns—one

micron recommended—and oil content not to exceed one part per million).

Table III: Physical Specifications

Housing Material

Cast, powder-painted aluminum, stainless steel

Soft Goods

Buna-N / Florosilicone

Weight

8.3 pounds (3.9 kg) aluminum

20.5 pounds (9.3 kg) stainless steel

Table IV: Positioner Specifications

Deadband

<0.1% full scale

Repeatability

<0.05% full scale

Linearity

<0.5% (rotary), <0.8%, (sliding stem) full scale

Air Consumption

<0.3 SCFM (0.5 Nm

3

/hr) @ 60 psi (4 bar)

Air Supply

30-150 psig (ISA 7.0.0.1 compliant)