Flowserve 3400IQ Digital Positioner User Manual

Page 51

Advertising
background image

1

Logix 3400IQ Digital Positioner FCD LGENIM3401-00 – 06/06

flowserve.com

Figure 13: Spool Valve Cover Assembly

4DSFX

4QPPM7BMWF$PWFS

1. Make sure the valve is bypassed or in a safe condition.

2. Disconnect the power and air supply to the unit.

3. Remove the driver module cover (Figure 15), using a flat bar or plate in the slot to turn the

cover.

4. Remove the spool valve cover by removing the screw and sliding the cover assembly backwards

until the tab is clear of the slot (Figure 13). The sheet metal cap, hydrophobic filter, and O-ring
should be removed with the spool valve cover. It is not necessary to take these parts out of the
spool valve cover.

5. Being careful not to lose the nylon washer, remove the Phillips-head screw that attaches the

driver module to the main housing (Figure 14).

Figure 14: Spool and Block

4QPPM7BMWF

4DSFX

/ZMPO

(BTLFU

%SJWFSUP

)PVTJOH4DSFX

4QPPM

4QPPM

7BMWF

#MPDL

)PVTJOH

Advertising