Installation – Flowserve HV 215 User Manual
Page 24

24
Cable routing
Installation
– continued –
Provide tank car with a guide sleeve
Y for the tension rope.
The position of the guide sleeve
Y must enable the tension rope to leave the control unit X of the bottom valve
at an angle of 45°.
See drawing on page 4
. The tension rope supplied by the manufacturer is 500 mm long and must be cut to the required length.
2. To connect the tension rope with the rail hook
C or the tension rope operating device, provide the tension
rope with a ring
D according to DIN 26026.
Note that this ring
D is not scope of the GESTRA supply!
Use the supplied wire clamp to attach the ring
D. Fasten the screws of the wire clamp with a torque of 2 Nm.
Attention
Do not pass the tension rope over sharp edges.
The lay-out of the tension rope, the guide sleeve
Y and the ring D for attaching the tension rope
operating device must comply with DIN 26026 and EN 256-3.
520
270
Tension rope
Guide sleeve
If the valve is open
At damper level 060
Upper edge of rail
Ring for attaching the tension
rope operating device