Servicing, Replacing control unit of bottom valve – Flowserve HV 215 User Manual
Page 42
42
Replacing control unit of bottom valve
Servicing
– continued –
In the control unit the ball valve with the tension rope will be replaced.
To remove the item proceed as follows:
See drawing further down
. Disengage the spring from the lever of the ball valve .
2. Detach the hydraulic hoses .
3. Unscrew the two hexagon nuts and their locking washers and remove the ball valve .
To install the item proceed as follows:
. Use two hexagon-head cap screws and hexagon nuts with washing lockers to fix the ball valve
to the support with a torque of 25 Nm.
2. Attach the connections for the hydraulic hoses .
3. Engage the spring in the lever of the ball valve .
42
36
41
39
40
36
38
39
40
36
37
41
42
36
Attention
The specified torques must be strictly observed.
42
41
36 37
38 39 40