Type of maintenance

Time interval

Activity

Check
oil level

When necessary,

during main inspection

at the latest (every 4 yrs.)

The level in the tank of the hydraulic hand pump

must be above the lower marking on the dip stick.

Check
tightness

When necessary,

during main inspection

at the latest (every 4 yrs.)

Make sure that oil cannot escape at connections,

joints and T-type screwed unions.

If necessary, retighten respective connections.

Check
valve lift

When necessary,

during main inspection

at the latest (every 4 yrs.)

With the hydraulic system closed, after approx. 6 lifts

of the hydraulic hand pump both indicating pistons

must be completely extended (height approx. 46 mm).

Check
holding pressure

When necessary,

during main inspection

at the latest (every 4 yrs.)

With the hydraulic system closed, both bottom valves

must withstand a constant pressure for two hours

without closing.

Check
rapid-action closing

When necessary,

during main inspection

at the latest (every 4 yrs.)

When disengaging the tension rope the rapid-action

closing must take place within one second and

the indicating pistons must be at the lower marking.

Check
completeness

When necessary,

during main inspection

at the latest (every 4 yrs.)

Both operating devices must have two emergency operating

screws each. These emergency operating screws must be

screwed in the rear wall.

Connecting lines

Type of maintenance

Time interval

Activity

Check
tightness

When necessary,

during main inspection

at the latest (every 4 yrs.)

Make sure that no oil can escape

at connecting joints and T-type screwed unions.

If necessary, retighten respective connections.