Technical Data

Oil detector & alarm ORGS 11-2

Test approval
ORGS 11-2: GL 17106-00 HH

Admissible service pressure
6 barg (87 psig)

Admissible service temperature
110 °C (230 °F)

Flow velocity
100 – 300 l/h, recommended 200 l/h

Pressure drop

∆∆∆∆∆

p

v

0.06 bar (under test conditions)

Raising of alarm
Oil content limit: approx. 50 ml

Water inlet, draining,
Ball valve, screwed EO 12 L

Water outlet
Ball valve, screwed EO 10 L

Weight
Approx. 7.4 kg

Electrode ORGS 11-1 (component of ORGS 11-2)

Connection
Screwed 1" BSP (DIN ISO 228-1)

Materials
Body:

G AlSi8Cu3

Stem:

1.4571 CrNiMoTi 17 12 2

Electrode rods:

1.4571 CrNiMoTi 17 12 2

of measuring electrodes: 5 mm

Protection
IP 65 to DIN EN 60529

Admissible ambient temperature
70 °C

Cable entry
Cable glands with integral cable clamps
M 16 x 1.5 (PG 19)
M 20 x 1.5 (PG 16)

Mains supply
115/230 V ± 10 %, 50/60 Hz
The transformer is of the split-bobbin
type according to VDE 0551

Special voltage
24 V ± 10 %, 50/60 Hz