Manual override – Flowserve CEA Series Limitorque Automax User Manual

Page 22

Advertising
background image

Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14

22

Magnet Puck Adjustment

If for any reason the black plastic EMC/EMI controls cover is removed
the indicator “puck” magnet will need to be timed such that the cor-
rect indication will be shown on the dome window when the actuator
controls cover is screwed down to the proper height.

Prior to adjustment the actuator must be in the Closed/CW position.
Using a 3/32 hex head wrench, loosen the socket head cap screw
and align the wrench with the controls cover set tab located on the
housing. See Figure below.

5. Manual Override

Manual override is provided as standard with each actuator. The
override requires minimum force to operate (less than 7lbs force) and
is spring loaded, push to engage. When engaged the worm shaft is
declutched from the motor drive to provide safe operation. The spring
loaded design ensures the override will not accidentally be left in the
By-Pass condition.

NOTE: If power is present and the handwheel is engaged and

rotated, the motor will power on but not impact rotation.