Assembly, Worcester controls – Flowserve 90 Series Limit Switch Kit User Manual

Page 2

Advertising
background image

1. ASSEMBLY

a. M2 – TWO SPDT MECHANICAL SWITCHES

M4 – FOUR SPDT MECHANICAL SWITCHES

P6 – TWO AC PROXIMITY SWITCHES

P8 – TWO DC PROXIMITY SWITCHES

1. STACK two switches (item 1) and attach to the adjustment

plate (item 2), as shown above, using two #4-40 x 1" screws
(item 3) provided.

Note: M2, M4 only – One of the screws will thread into a
tapped hole in the adjustment plate while the other engages a
clearance hole without threads.

2. For M2, M4 only – Assemble the switches and adjustment

plate to the baseplate (item 4), as shown below, using the
“loose” #4-40 x 1" screw and the #4-40 x

3

/

8

" screw (item 5)

and #4 washer (item 6). For P6, P8: Assemble the switches to
the baseplate using the two #4-40 x

3

/

8

" screws and the #4

washer. Move the adjustment plate to a middle position and
tighten the screws.

3. FOR M4 ONLY: Stack the other two switches and assemble to

the baseplate using the remaining two #4-40 x 1" screws
(item 7).

b. D2 - TWO DPDT MECHANICAL SWITCHES

1. Attach the mounting plate (item 2) to the baseplate (item 4) in

the location shown using the two #4-40 x

3

/

8

" flat head screws

(item 3) and the one #4-40 x

3

/

8

" round head screw (item 6).

2. Assemble the switches (item 1) to the mounting plate with the

two #6-32 screws (item 5).

Flow Control Division

Worcester Controls

2

Limit Switch Kit for Series 90 Modular Accessory System

WCAIM2044

Advertising