Technical data – Flowserve NRG 26-40 User Manual

Page 6

Advertising
background image

6

NRG 26-40

Type Approval Nº

TÜV · WR · 04-399
Max. service pressure

32 bar g at 238°C
Connections

Screwed ¾" BSP, EN ISO 228-
Materials

Case: Die cast aluminium 3.26 (G AlSi8Cu3)

Stem: S. S. .457 (X6CrNiMoTi7-2-2)

Measuring electrodes: S. S. .440 (X5CrNiMo7-2-2)

Electrode insulation: PTFE
Length supplied/measuring range

see

Fig. 2

Supply voltage

8 – 36 V DC
Current consumption

65 mA
Fuse

Thermal fuse T

max

= 80 °C

Hysteresis

-2 K
Data exchange

CAN bus acc. to DIN ISO 898, CANopen protocol
Attenuation, signal output

9 sec.
Indicators and adjustors

 green LED “C

an

bus

CommuniCation

 red LED “b

us

fault

 0-pole code switch for node ID and baud rate settings
Electric connection

M 2 sensor connector, 5 poles, A-coded,

M 2 sensor jack, 5 poles, A-coded
Protection

IP 65 to DIN EN 60529
Max. admissible ambient temperature

70 °C
Weight

approx. 2.5 kg

Technical data