Delta Tau PMAC2A-PC/104 User Manual

Page 63

Advertising
background image

PMAC2A PC104 Hardware Reference Manual

Acc-1P Connector Pinouts

57

J4 (JMACH2): Machine Port
Connector (34-Pin Header)

Front View

Pin# Symbol Function

Description

Notes

1

FLG_5_6_V

Input

Flags 5-6 Pull-Up

2

FLG_7_8_V

Input

Flags 7-8 Pull-Up

3

GND

Common

Digital Common

4

GND

Common

Digital Common

5

HOME5

Input

Home-Flag 5

10

6

HOME6

Input

Home-Flag 6

10

7

PLIM5

Input

Positive End Limit 5

8,9

8

PLIM6

Input

Positive End Limit 6

8,9

9

MLIM5

Input

Negative End Limit 5

8,9

10

MLIM6

Input

Negative End Limit 6

8,9

11

USER5

Input

User Flag 5

12

USER6

Input

User Flag 6

13 PUL_5 Output

Pulse

Output

5

14 PUL_6 Output

Pulse

Output

6

15 DIR_5 Output

Direction

Output

5

16

DIR_6

Output

Direction Output 6

17 EQU5 Output

Encoder

Comp-Equal

5

18 EQU6 Output

Encoder

Comp-Equal

6

19

HOME7

Input

Home Flag 7

10

20

HOME8

Input

Home Flag 8

10

21

PLIM7

Input

Positive End Limit 7

8,9

22

PLIM8

Input

Positive End Limit 8

8,9

23

MLIM7

Input

Negative End Limit 7

8,9

24

MLIM8

Input

Negative End Limit 8

8,9

25

USER7

Input

User Flag 7

26

USER8

Input

User Flag 8

27 PUL_7 Output

Pulse

Output

7

28 PUL_8 Output

Pulse

Output

8

29

DIR_7

Output

Direction Output 7

30

DIR_8

Output

Direction Output 8

31

EQU7

Output

Encoder Comp-Equal 7

32

EQU8

Output

Encoder Comp-Equal 8

33

B_WDO

Output

Watchdog Out

Indicator/Driver

34

No Connect

Note 1: Pins marked PLIMn should be connected to switches at the positive end of travel. Pins marked MLIMn

should be connected to switches at the negative end of travel.

Note 2: Must be conducting to 0V (usually GND) for PMAC to consider itself not into this limit. Automatic limit

function can be disabled with Ix25.

Note 3: Functional polarity for homing or other trigger use of HOMEn controlled by Encoder/Flag Variable I9n2.

HMFLn selected for trigger by Encoder/Flag Variable I9n3. Must be conducting to 0V (usually GND) to
produce a 0 in PMAC software.

Advertising