Settings – Fronius String Control 250/30 User Manual

Page 38

Advertising
background image

36

Settings

General

All settings for the Fronius String Control 250/30 are applied using the "Fronius Solar.ac-
cess" software.

Step one

Install the Fronius Solar.access software on the PC
Administration / Create system
Systems / [Name of the system] / Settings / String Control

Possible settings
for the Fronius
String Control
250/30

(1)

Selecting the number (address) of
the Fronius String Control 250/30 to
be set

(2)

Strings per measuring channel

(3)

Limit values:
- max. energy deviation in %
- threshold value in Ah per string

Strings per meas-
uring channel

Enter the number of PV module strings for each measuring channel.
This results in automatic correction of measuring channel deviations, which would only be
required if there were a different number of strings per channel.

Max. energy devi-
ation

The 5 measuring channels record the total current from the connected solar module strings
over the entire feed-in day. In the evening, the Fronius String Control 250/30 calculates the
mean for all the measuring channels and compares the current on each measuring chan-
nel with the mean for all measuring channels. If the Fronius String Control 250/30 detects
that one of the measuring channels is deviating from this mean, a status code is sent to the
Fronius Datalogger.

In the "Max. energy deviation" input box, define the deviation as a % above which a meas-
uring channel should be classified as faulty.

Standard value for the max. energy deviation: 5% - 10%

Note any specifications provided by the solar module manufacturer.

Threshold

The average electric charge of all strings in Ah at which the evaluation of the "max. energy
deviation" is to start.
This will prevents status codes due to bad weather.