EN

Interrupting
charging

Press Start/Stop button to interrupt charging:

-

The display shows the number of ampere-hours already
charged

-

Press Start/Stop button again to resume charging

Press the Info button several times in a row to display the parameters in the
following sequence:

Retrieving para-
meters during
charging

Example: current battery
voltage

Example: current charging
current

Example: ampere-hours
already charged

Charging deep-
discharge batte-
ries

In the case of deep-discharge batteries (voltage < 2 V), charging must be started manu-
ally as follows:

9.

Charging begins

If no buttons are pressed within 5 seconds, the charger
returns to the main menu.

Warning! Risk of serious damage as the result of
-

incorrectly connected charging terminals. The terminal polarity reversal
facility is inoperative in „Charging deep-discharge batteries back-up“
mode.

-

incorrectly set battery voltage.

Connect charging terminals to correct poles and ensure proper electrical
connection to vehicle terminals. Note battery voltage.

Example: 12 V vehicle voltage

Caution! Risk of damage when attempting to charge a faulty battery. Before
charging, ensure that the battery to be charged is fully functional.

Disconnecting
the battery

1.

Press Start/Stop button

2.

- Disconnect (-) terminal from battery or vehicle earth (ground)

3.

Disconnect (+) terminal from battery

1.

Plug in charger mains plug

2.

Set mode

3.

Set battery capacity

4.

Connect the battery

5.

Press and hold Start/Stop button for approx. 5 sec. - „Charging deep-discharge
batteries/back-up mode“ menu item is activated

6.

Select battery voltage by pressing Up/Down buttons

7.

Confirm selected voltage by pressing Start/Stop button

8.

Confirm correct terminal connection prompt by pressing Start/Stop button

Advertising