Back-up mode

6.

Confirm selected voltage by pressing Start/Stop button

7.

Connect charging terminals to correct vehicle pole terminals

8.

Confirm correct terminal connection prompt by pressing Start/Stop button

9.

Charger starts back-up mode

10. Change battery
11. Connect vehicle pole terminals to correct poles on new battery
12. End back-up mode by pressing Start/Stop button

Important! If the Start/Stop button is not pressed, the charger will still be in back-up
mode when next switched on.

13. Disconnect charger from mains supply
14. Remove charging terminals from vehicle pole terminals

Provides a power supply to the vehicle while the battery is being changed. Electrical
equipment such as window lifters, etc. may be used. Because the charger output voltage
is regulated, the vehicle electronics are not adversely affected.

If no buttons are pressed within 5 seconds, the charger
returns to the main menu.

Warning! Risk of serious damage as the result of
-

incorrectly connected charging terminals. The terminal polarity reversal
facility is inoperative in „Charging deep-discharge batteries back-up“
mode.

-

incorrectly set vehicle voltage.

Connect charging terminals to correct poles and ensure proper electrical
connection to vehicle terminals. Note vehicle voltage.

Example: 12 V vehicle voltage

1.

Switch off engine

2.

Turn off ignition

3.

Plug in charger mains plug

4.

Press and hold Start/Stop button for approx. 5 sec. - „Charging deep-discharge
batteries/back-up mode“ menu item is activated

5.

Select battery voltage by pressing Up/Down buttons

Automatic/fixed
voltage selection

This menu item
-

permits automatic voltage detection when charging starts (factory setting)

-

allows fixed setting for the battery being charged (e.g. only used to charge 12 V
batteries)

1.

Plug in charger mains plug

2.

Press and hold Info button for approx. 5 sec - „Automatic/fixed voltage selection“
menu item is activated.

3.

Select voltage by pressing Up/Down buttons

Automatic battery voltage
selection

Example: manually fixed
setting for 12 V battery

4.

Confirm selected voltage by pressing Start/Stop button (10)