Specifications

General/Environmental

Location (rack-mounted IBU)..................................................... Ordinary (non-classified) indoor/outdoor

FCC Registration Number .................................................................................... ADGUSA-65066-TE-E

Ringer Equivalence Number (REN)................................................................................................... 0.4B

Operating temperature range

I.S. Series Telephones ......................................................... -40

° F to +140° F (-40° C to +60° C)

Rack equipment ..................................................................... +32

° F to +104° F (0° C to +40° C)

Relative humidity .................................................................................. 95% (non-condensing) maximum

Maximum safe wiring distance between IBU and I.S. Series telephones

Standard wire types ......................................................................................................................... 1 mile

Using GTC 60059-001 conductor ............................................................................................... 1.5 miles

Using GTC 60021-301 conductor ............................................................................................... 1.5 miles

Wiring

Construction.......................................................................................................................... Twisted pair

Type.......................................................................................................................................... Shielded*

Conductor size (minimum) ......................................................................................................... 24 AWG

Wiring loop resistance (maximum) ............................................................................................ 275 ohms

Wiring capacitance (maximum) .................................................................................................. 0.316 uF

*Shielded cable is required where multiple I.S. telephone wires are routed together.

Shipping weight

Model 265 Line Card.................................................................................................... 2.88 lbs. (1.31 kg)

Model 266 Power Supply ............................................................................................. 4.88 lbs. (2.22 kg)

Model 267 Subrack Assembly ...................................................................................... 8.42 lbs. (3.83 kg)

Model 268 Patch Panel ................................................................................................. 1.56 lbs. (0.71 kg)

Dimensions

Model 265 Line Card....................................... 5.06 H

× 2 W × 12.9 D; inches (128.6 × 50.8 × 327.6 mm)

Model 266 Power Supply ............................. 5.06 H

× 3.8 W x 12.1 D; inches (128.6 × 96.5 × 307.3 mm)

Model 267 Subrack Assembly ..................... 5.25 H

× 19 W × 14.5 D; inches (133.3 × 482.6 × 368.3 mm)

Model 268 Patch Panel ........................... 1.75 H

× 19.75 W × 1.25 D; inches (44.5 × 501.65 × 31.75 mm)