Electrical Connection

The Model 13310-201 Driver has a 16-ohm impedance, and if used singly, connects to the 16-ohm
amplifier output tap. If two drivers are used, connect in parallel to the 8-ohm amplifier output tap.

The Model 13310-202 Driver has an 8-ohm impedance and if used singly, connects to the 8-ohm
amplifier output. If two drivers are used, connect in series to the 16-ohm output.

The Model 13310-203 Driver has a 70.7 V transformer. Connect the transformer for the power level
desired (30 watts max.). See Figure 2.

CAUTION

Installation must be in accordance with National

Electrical Code for the appropriate hazardous area classification.

1. Select the speaker mounting assembly based on the horn being used.

Refer to the chart at the right. The suggested mounting height is
9 feet (2.7 meters) above the floor.

2. In hazardous areas, use the speaker mounting assembly to support the

speaker only. Do not route electrical connections through the mounting
assembly.

Figure 2. Front and Rear Halves of Model 13310-203 Driver Assembly – Output Tap Locations

Specifications

Power capacity..................................................................................................... 30 watts continuous power

Impedance ................................................................................................. 16 ohms (voice coil) – 13310-201

8-ohms – 13310-202

70 V – 13310-203

Conduit attachment ....................................................................... Standard 1/2 inch (1.27 cm) pipe conduit

Horn coupling ............................................................................... Standard 1-3/8 inch (3.5 cm) - 18 threads

Approval ..................... UL listed [E71922] for Class I, Groups B, C and D, Hazardous Gas Areas (Div. 1)

Horn

Series

Mounting

Assembly

13302 415A
13304 415A
13305 413A
13306 415A
13309 415A
13340 415A