Mounting – GAI-Tronics 733-001 Page/Party Weatherproof Non-Metallic Single-Party Amplifier Enclosure (115 V AC) User Manual

Page 2

Advertising
background image

Pub. 42004-426B

733-001 Single-Party Weatherproof Non-Metallic 120 V AC Amplifier Enclosure

Page:

2 of 7

f:\standard ioms - current release\42004 instr. manuals\42004-426b.doc
08/11

Mounting

The 733-001 Enclosure is not supplied with conduit or cable openings. Drill or punch these openings
using the template supplied before mounting the enclosure. The recommended cable entry point is via
the bottom of the enclosure near the rear surface to prevent moisture from dripping onto the terminals or
PCBAs. A secondary location for cable entry is in the top of the enclosure toward the sides. Avoid the
top center, as it may interfere with the plug-in amplifier receptacle. Under no circumstances should cable
entries be made in the side of the enclosure as this may interfere with the installation of the plug-in
amplifier.

For specific details including mounting hole dimensions, refer to Figure 1. When mounting the
enclosure, use caution to avoid damaging the terminal blocks inside. The suggested mounting height for
all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure.

Figure 1. 733-001 Single-Party Weatherproof Non-Metallic Enclosure Mounting Details