Specifications – GAI-Tronics 12600-002 Line Current Boost Circuit Assemblies User Manual

Page 5

Advertising
background image

Pub. 42004-433C

Model 12600-002 and 12600-40x Line Current Boost Circuit Assemblies

Page: 5 of 5

f:\standard ioms - current release\42004 instr. manuals\42004-433c.doc
07/11

Specifications

Model 12600-002

Power supply............................................................................................. 48 V dc @ 250 mA (unregulated)

Input voltage to plug-in power supply .................................................................... 120 V ac +10% @ 60 Hz

Input power to plug-in power supply...................... Off-hook: 6.0 W maximum; On-hook 4.0 W maximum

Dimensions ....................................................................4.50

× 3.00 × 2.00 inches (114.3 × 76.2 × 50.8mm)

Weight..................................................................................................................................................0.5 lbs.

Models 12600-401 and 402

Input voltage ............................................................................................................................ 48 V dc +20%

Dimensions (without mounting brackets) .................17.00

× 9.00 × 1.75 inches (431.8 × 228.6 × 44.4 mm)

With brackets ........................................19.00

× 10.00 × 1.75 inches (482.6 × 254.0 × 44 mm)

Weight................................................................................................................................ 8.5 lbs. maximum

Models 12600-403 and 404

Input voltage .......................................................................................................... 85–264 V ac @ 50/60 Hz

Dimensions (without mounting brackets) .................17.00

× 9.00 × 1.75 inches (431.8 × 228.6 × 44.4 mm)

With brackets ........................................19.00

× 10.00 × 1.75 inches (482.6 × 254.0 × 44 mm)

Weight................................................................................................................................ 8.5 lbs. maximum

Environmental

Operating temperature ............................................................................................................ 40º C to +70ºC

Supplemental line current ................................................................................................... 30 mA dc +5 mA

PABX interface requirements:

Minimum on-hook tip/ring voltage.................................................................20 V dc (LCBC disconnected)

Minimum loop current ...................................................................................8 mA dc (LCBC disconnected)

Maximum recommended loop current .........................................................40 mA dc (LCBC disconnected)

Optional ringer requirements ....................................................................................................Type B ringer

N

OTES

:

The supplemental line current has a negative temperature coefficient promoting temperature stability for
both the LCBC and the telephone instrument connected to the LCBC.

Transient protection .....................Meets the requirements of FCC Part 68 Type A & B transient protection

Advertising