Procedure

WARNING

Disconnect power before making any repairs to a hazardous area station.

N

OTE

: The internal outer edge of the front cover is machined. Take precautions to ensure that the finish

is preserved. If damaged, the explosion-proof integrity can be lost.

Figure 1. Replacement Handset with Cord and Amplifier Assembly

1.

Turn off power.

2.

Remove the 14 bolts (Ref. 1 typ.) from the front cover (Ref. 2) using a socket or a combination
wrench.

3.

Lift off the front cover, and disconnect the flat ribbon cable (Ref. 3).

4.

Remove the four screws (Ref. 4) that hold the amplifier assembly (Ref. 5) to the front cover (Ref. 2).