GAI-Tronics 12530-001 Transformer/Conn Kit (56116-001) User Manual

Transformer/connector subassembly replacement kit, Confidentiality notice, General information

Advertising
background image

Pub. 42003-040B

GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA

610-777-1374

„ 800-492-1212 „ Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

Transformer/Connector Subassembly

Replacement Kit

Model 12530-001

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.

General Information

The Model 12530-001 Transformer/Connector Replacement Kit is for use on the following models:
701-201, 701-202, 701-204, 701-205, and 723-001.

Installation

Removal of Existing Subassembly

1. Remove the amplifier from the enclosure by loosening the 4 front panel screws.

2. Using a hex nut driver, loosen the four screws (two are on the top surface and two are on the bottom)

holding the front panel to the chassis.

3. Separate the chassis from the front panel of the amplifier.

4. Locate the transformer by first locating the white connector on the upper right corner of the PCBA.

The transformer has five wires connecting it to the connector: black, green, yellow, blue, and brown.

5. Remove both of the self-tapping screws on the top of the amplifier.

6. Unplug the connector from the PCBA and remove the transformer/connector subassembly.

Set the clips aside to use on the new transformer.

Advertising