GAI-Tronics 12556-001 Smart Station Handset Board Replacement Kit User Manual

Pcba replacement kit, Confidentiality notice, Instructions

Advertising
background image

Pub. 42003-160A

GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA

610-777-1374

„ 800-492-1212 „ Fax: 610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ® C O R P O R A T I O N

A H U B B E L L C O M P A N Y

PCBA Replacement Kit

M

ODEL

12556-001

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive
business and technical information which is confidential and proprietary to GAI-Tronics. GAI-Tronics
retains all intellectual property and other rights in or to the information contained herein, and such
information may only be used in connection with the operation of your GAI-Tronics product or system.
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

Instructions

The Model 12556-001 PCBA Replacement Kit contains one Model 69228 handset amplifier PCBA for use
in GAI-Tronics SmartHandset™ stations and SmartAmplifier™ stations.

WARNING

Remove the power from the station prior to servicing.

Removing the Old PCBA

1. Loosen the four screws at the corners of the front panel, and pull the plug-in the amplifier from the

enclosure. All maintenance work from this point on should be performed at a work bench with the
operator properly grounded to avoid static discharge.

2. Loosen the four chassis screws (Phillips) on the top and bottom of the unit.

3. Carefully slide the chassis to the left, and separate it from the front panel.

CAUTION

The power supply harness inside is short; do not pull it apart abruptly.

4. Remove the power supply wire harness from J6 on the Model 69241 PCBA by pressing the tab on the

locking connector.

5. Remove the aux/subset connector at J2 from the Model 69228 PCBA (for Model 701-804 only).

6. Disconnect the spade terminals at E1 through E7. Needlenose pliers may be required.

7. Remove the four screws that secure the Model 69228 PCBA. DO NOT DISCARD THE

HARDWARE. Disconnect the assembly by grabbing the PCBA at the sides near the J1 connector.
Unplug it from the PCBA below it.

Advertising