WARNING: Installation should only be made by

qualified persons who are familiar with the safety
procedures required for the installation of the prod-
uct, who are equipped with the proper tools and
testing instruments, and who have achieved proper
certification of licensing. Installations made by un-
qualified persons can result in the risk of injury or
electrical shock which can be serious or even fatal.

INSTALLATION OF LISTED B-1 VENT

VENTING INSTALLATION

Continued

Figures 22 through 24 show other options for the gas vent. When
venting through a side wall your vent pipe must have the proper
temperature rating (see Figure 24). Manufacturer's clearances must
also be maintained. Consult the authority having jurisdiction in your
area regarding venting through side wall.

Figure 22 - Vertical
Venting Through Ceiling
Using Two 90
º Elbows

Figure 23 - Vertical Venting
Configuration Through Chimney

Figure 24 - Venting Through a Side Wall

Figure 21 - Typical B-Vent Installation

Round Top

Storm Collar

Flashing

Roof Support

25mm (1") Clearance to
Combustible Material

Firestop
Spacer

Keep Electrical Wires and
Building Insulation Away from
Gas Vent and Out of the
Required Air Space

Enclosure
Wall

Gas Vent
Length

25mm (1") Clearance to
Combustibles

Support
Plate

Adjustable
Length

INSTALLING VENT SYSTEM IN A CHASE

A chase is a vertical box-like structure built to enclose venting that runs
along the outside of a building. A chase is not required for such venting.

NOTICE: Treatment of firestops and construction of
the chase may vary from building type to building
type. These instructions are not substitutes for the
requirements of local building codes. You must fol-
low all local building codes.

Note:

When installing in a chase, you should insulate the chase as

you would the outside walls of your home. This is especially
important in cold climates. Minimum clearance between vent pipes
and combustible materials such as insulation is 1".

VENTING INSTALLATION

Type B-Vent Installation (Cont.)
Installation of Listed B-1 Vent
Installing Vent System In A Chase