11

103296

Note: Clearances are the
same if using optional
cabinet mantel or built-in
installation.

MINIMUM CLEARANCE
Side Wall - 16 " Cabinet and

Face Mantel

Ceiling - 42" Corner Mantel
Floor - 0"

Figure 6 - Minimum Clearance to Wall and Ceiling

,,,,,,

,,,,,,

,,,,,,

,,,,,,

,,,,,,

,,,,,,

,,,,,,

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

,,,,,,,

,,,,,,,

,,,,,,,

,,,,,,,

,,,,,,,

,,,,,,,

,,,,,,,

42"

16"

Face or

Cabinet

Mantel

Corner

Mantel

12"

INSTALLING

Continued

Mantel Clearances for Built-In Installation

If placing custom mantel above built-in firebox, you must meet minimum clearance
between mantel shelf and top of firebox opening.

If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.

Distances to
Underside of
Mantel

Underside of
Mantel Shelf

20"

24

1/2

"

27

1/2

"

30"

All minimum
distances are
in inches

Top of
Fireplace
Opening

2

1

/2

"

6"

8"

10"

Figure 7 - Minimum Mantel Clearances for Built-In Installation

Mantel Shelf

Mantel Clearances for Conventional Installation