INSTALLING

Continued

Built-In Installation of Blower Accessory

1. Install blower assembly per instruction sheet included.
2. Before replacing bottom of firebox, remove screw holding duplex outlet to the

support bracket in the bottom of firebox. Remove duplex outlet.

3. Clamp electrical cable into firebox through smallest hole using strain relief provided.
4. Route wires from electrical box through hole in side of heater and hole in

support bracket (see Figure 9).

5. Connect wires from the electrical box to duplex outlet. Match wire colors to

those indicated on duplex outlet. Be sure to connect ground wire.

6. Replace duplex outlet with screw.
7. Plug blower power cord into duplex outlet.
8. Replace bottom of firebox.

NOTICE

A certified electrician must connect electrical wiring to duplex
outlet for built-in installation. Follow all local codes.

Figure 9 - Routing Blower Accessory Power Cord for Built-In Installation

Cables From
Electrical
Source

Duplex Outlet

Screw

Blower Power Cord

Blower

Support bracket

INSTALLING BLOWER ACCESSORY (Model FB32C only)

You may install blower accessory GA3500A with conventional installation (page
15) or with built-in installation (page 17) with model FB32C only. To install
blower accessory, see instruction sheet included with the kit.

Conventional Installation of Blower Accessory

1. Install blower assembly per instruction sheet included in blower accessory kit.
2. Before replacing bottom of firebox, route blower power cord through hole in

support bracket in bottom of firebox and through hole in side of firebox to
grounded, three-prong 120 volt electrical outlet (see Figure 8). Plug electrical
cord into outlet.

3.

Replace bottom of firebox.

Figure 8 - Routing Blower Accessory Power Cord for

Conventional Installation

Electrical
Outlet

Side Opening

Support Bracket Opening

Blower Power Cord

Blower

Advertising