103296

Cut to

7 1/4"

Length

INSTALLING

Continued

4. Route flexible gas line from manual shutoff valve into firebox through side.

5. Attach gas log heater base to firebox bottom with four screws included with

base (see Installing Heater Base Assembly in log set owner’s manual).

6. Replace firebox bottom and secure with screws.

NOTICE

Most building codes do not permit concealed gas connections. A
flexible gas line is provided to allow accessibility from the firebox.
The flexible gas supply line connection to the manual shutoff
valve should be accessible.

IMPORTANT:

If installing a VL18N/P, VL18NT(A)/PT(A), VL24N/P,

VL24NT(A)/PT(A), VS24NV(A)/PV(A), VS18NV/PV, VS24NTA/PTA,
VS18NTA/PTA, CF18N/P, CF18NT(A)/PT(A), CF24N/P, CF24NT(A)/PT(A),
CFS24NV(A)/PV(A), CF18NV/PV, CF24NTA/PTA, or CF18NTA/PTA gas log
heater, locate two mounting brackets included with appliance. Measure these
brackets. If overall length is 9 1/4", cut 2" off rear of each bracket with hacksaw
(see Figure 11).

Figure 11 - Cutting Brackets

Figure 10 - Removing Firebox Bottom

INSTALLING LOG HEATER IN FIREBOX

WARNING ICON

G 001

CAUTION

Do not pick up log base assembly by burners. This could damage
burners. Only handle base by grates.

1. Remove four screws holding firebox bottom in place.
2. Lift and remove firebox bottom (see Figure 10).
3. If installing GA3500A Blower Accessory (Model FB32C only), see Installing

Blower Accessory, page 12.

Heater Base

Mounting
Bracket

Firebox Bottom

Screws