Operating heater, Inspecting burner, Manual lighting procedure – Desa CGN10L User Manual

Page 18

Advertising
background image

18

103546

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the PILOT position.

2. Press in control knob and turn clockwise

Clockwise

to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 10, page 12).
2. Follow steps 1 through 5 under Lighting Instructions
, pages 16 and 17.
3. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

4. Keep control knob pressed in for 30 seconds after pilot is lit. After 30

seconds, release control knob.

5. Replace front panel.

OPERATING

HEATER

Continued

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

INSPECTING

BURNER

GRH/OV 009

GOOD PILOT

Thermocouple

Pilot Burner

GRH/OV 010

BAD PILOT

Pilot Burner

Thermocouple

Figure 17 - Correct Pilot Flame Pattern

Figure 18 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 18

• turn heater off (see To Turn Off Gas to Appliance, above)
• see Troubleshooting, pages 20 through 23

Continued

Advertising
This manual is related to the following products: