Inspecting burner, Notice, Warning – Desa CGN10L User Manual

Page 19

Advertising
background image

19

103546

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

NOTICE

Do not mistake orange flames with yellow tipping. Dust or other
fine particles enter the heater and burn causing brief patches of
orange flame.

BURNER FLAME PATTERN

Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the glass panel height.

INSPECTING

BURNER

Continued

WARNING ICON

G 001

WARNING

If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.

If burner flame pattern is incorrect, as shown in Figure 20

• turn heater off (see To Turn Off Gas to Appliance, page 18)
• see Troubleshooting, pages 20 through 23

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

Yellow
Tipping

(Model CGN6 will be lower due to lower input rating)

Figure 20 - Incorrect Burner Flame Pattern

Figure 19 - Correct Burner Flame Pattern

(Model CGN10A)

Advertising