103546

TROUBLE-

SHOOTING

Continued

OBSERVED
PROBLEM

When ignitor button
is pressed, there is
spark at ODS/pilot
but no ignition

ODS/pilot lights but
flame goes out when
control knob is
released

POSSIBLE
CAUSE

1. Gas supply turned off

or manual shutoff
valve closed

2. Control knob not in

PILOT position

3. Control knob not

pressed in while in
PILOT position

4. Air in gas lines when

installed

5. ODS/pilot is clogged

6. Gas regulator setting is

not correct

1. Control knob not fully

pressed in

2. Control knob not

pressed in long enough

3. Manual shutoff valve

not fully open

4. Thermocouple connec-

tion loose at control
valve

5. Pilot flame not touch-

ing thermocouple,
which allows thermo-
couple to cool, causing
pilot flame to go out.
This problem could be
caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot

6. Thermocouple dam-

aged

7. Control valve damaged

REMEDY

1. Turn on gas supply or

open manual shutoff
valve

2. Turn control knob to

PILOT position

3. Press in control knob

while in PILOT
position

4. Continue holding down

control knob. Repeat
igniting operation until
air is removed

5. Clean ODS/pilot (see

Cleaning and Mainte-
nance
, page 20) or
replace ODS/pilot
assembly

6. Replace gas regulator

1. Press in control knob

fully

2. After ODS/pilot lights,

keep control knob
pressed in 30 seconds

3. Fully open manual

shut-off valve

4. Hand tighten until

snug, then tighten 1/4
turn more

5. A) Contact local

natural gas company

B) Clean ODS/pilot
(see Cleaning and
Maintenance
, page 20)
or replace ODS/pilot
assembly

6. Replace thermocouple

7. Replace control valve

Continued