1-13

X-Y Command THC

Product Configuration Manual

SPECIFICATIONS & UNIT MOUNTING

Torch Breakaway Kit 128281 (Optional)

The breakaway kit includes all hardware required to mount the breakaway to the X-Y lifter as shown
in Figure 1-12. Detailed installation instructions are included with the THC system. Additional require-
ments are listed below:

1.

Install the breakaway pressure switch wiring lead (6) to the CNC emergency stop circuit.

2.

Mount the filter/regulator (7) per Figure 1-12.

3.

Plumb the air supply to the regulator (7) inlet port at 100 psi (6.9 bar) (recommended maxi-
mum pressure). The regulator inlet port size is 1/4 inch NPTF.

4.

See Figure 1-5 for torch-to-lifter mounting dimensions.