X-y command thc – Hypertherm THC X-Y Table Product Configuration User Manual
Page 16
Advertising
![background image](/files/789578/content/doc016.png)
1-13
X-Y Command THC
Product Configuration Manual
SPECIFICATIONS & UNIT MOUNTING
Torch Breakaway Kit 128281 (Optional)
The breakaway kit includes all hardware required to mount the breakaway to the X-Y lifter as shown
in Figure 1-12. Detailed installation instructions are included with the THC system. Additional require-
ments are listed below:
1.
Install the breakaway pressure switch wiring lead (6) to the CNC emergency stop circuit.
2.
Mount the filter/regulator (7) per Figure 1-12.
3.
Plumb the air supply to the regulator (7) inlet port at 100 psi (6.9 bar) (recommended maxi-
mum pressure). The regulator inlet port size is 1/4 inch NPTF.
4.
See Figure 1-5 for torch-to-lifter mounting dimensions.
Advertising