Weekly cleaning and inspection instructions, Inspect hoses and leads, Inspect for gas leaks – Hypertherm MAXPRO200 Preventive Maintenance Program User Manual

Page 11: Verify coolant flow, Check coolant level

Advertising
background image

MAXPRO200 Preventive Maintenance Program Instruction Manual 808800

7

Weekly cleaning and inspection instructions

Inspect hoses and leads

Visually inspect all air hoses, coolant hoses, and torch leads for wear, restrictions, or both. Look especially for:

Scrapes or cuts

Punctures

Chemical spills or burns

Kinks or bends that restrict flow or damage the hose or lead.

Replace all damaged hoses or leads. Refer to

Part numbers for MAXPRO200 cables, hoses, and leads on page 20 for

lengths and part numbers.

Inspect for gas leaks

For more information, see

Gas leak tests in the Maintenance section of your system’s instruction manual (807700).Verify

coolant flow

For more information, see

Coolant flow test in the Maintenance section of your system’s instruction manual (807700).

Verify coolant flow

1. Turn ON the power to the power supply and select the coolant flow

icon on the front panel of the power supply BEFORE the purge cycle
is complete. The flow switch will be overridden and coolant will
continue to flow for 30 seconds.

2. Record the flow rate in the maintenance log at the end of this

document.

Check coolant level

1. Open the cover of the coolant tank on the top of the power supply enclosure.

2. Verify that the tank is full of coolant.

3. If the level of coolant is below the full line, add coolant until it reaches the full line.

Full Line

Advertising