Routine maintenance, Service manual, Routine maintenance warning – Hypertherm Powermax350 Service Manual User Manual

Page 26: Aintenance

Advertising
background image

Service Manual

3-2

M

AINTENANCE

ROUTINE MAINTENANCE

WARNING

SHOCK HAZARD: Always turn off the power and unplug the cord before changing consumable
parts. Do not rely on the cap-on sensor switch to remove power. It is provided strictly for safety
backup. In the U.S., use a "lock-out / tag-out" procedure until the service or maintenance work is
complete. In other countries, follow appropriate national or local safety procedures.

Under severe conditions, routine maintenance should be performed more frequently.

Before Each Use

Check the air pressure.

Check the torch and consumables.

Every Week

Check the torch cap-on sensor system by listening for the micro-switch to "click" when the retaining cap is
loosened. Check the

Torch Cap Shutdown System as follows:

Turn power On (I) and loosen the torch retaining cap.

If shutdown system works properly, READY LED extinguishes and TORCH CAP LED illuminates.

If the shutdown system does not work properly, turn power Off (O) and check for proper air pressure,
blocked or leaking hose, or loose torch retaining cap. Check the system by retightening the retaining cap
and resetting the power as described above.

3 Months

Replace damaged or unreadable labels.

Service the filter and pressure regulator.

Check the air supply hose.

Replace any cracked parts.

Check the torch body and torch lead.

Replace the torch lead if the insulation is broken.

6 Months

Blow out or vacuum the inside of the power supply.

7-98