Service manual, Aintenance – Hypertherm Powermax350 Service Manual User Manual

Page 34

Advertising
background image

Service Manual

3-10

M

AINTENANCE

Problem

Cause/Solution

3. No cutting output; POWER ON and READY LEDs
illuminated; PRESSURE, TORCH CAP and OVER-
TEMP LEDs extinguished; fan operating.

4. No cutting output; POWER ON LED illuminated;
READY, PRESSURE, TORCH CAP and OVER-TEMP
LEDs extinguished; fan operating.

5. No control of cutting output.

2.5 Check resistance and connections of input

resistor R2 which is rated at 10 ohms

±

10 %.

Replace if necessary.

2.6 Check coil voltage and connections of control

relay CR6. Check continuity of coil and condition
of contacts. Replace if necessary.

2.7 Check transformer T1 for signs of winding failure.

Check continuity across windings and check
connections. Check secondary voltages. Replace
if necessary.

3.1 Check that the work clamp is connected.

3.2 Clean or replace worn consumables as

necessary.

3.3 Check resistance and connections of input

resistor R2 which is rated at 10 ohms

±

10 %.

Replace if necessary.

3.4 Check coil voltage and connections of contactor

control relay CR7. Check continuity of coil and
condition of contacts. Replace if necessary.

3.5 Check coil voltage and connections of control

relay CR6. Check continuity of coil and condition
of contacts. Replace if necessary.

3.6 Check coil voltage and connections of gas valve

GS1. Check continuity of coil. Replace if
necessary.

3.7 Check power control board PC1 and connections.

Replace if necessary.

3.8 Check safety control board PC2 and connections.

Replace if necessary.

4.1 Reset power switch S1.

4.2 Check safety control board PC2 and connections.

Replace if necessary.

5.1 115/230 Volt units: Check position of input voltage

selector switch S2.

5.2 Check power control board PC1 and connections.

Replace if necessary.

5.3 Check safety control board PC2 and connections.

Replace if necessary.