Functional block diagram, 200 volt, Figure 3-2.2, Functional block diagram, 200 volt unit – Hypertherm Powermax350 Service Manual User Manual

Page 30: Service manual, Aintenance

Advertising
background image

Service Manual

3-6

M

AINTENANCE

200 VAC

1 Ø Line Input

Power

Input

Resistor

R2

CR6

1

Power Switch S1

Provides on/off control of power to
main transformer T1.

2

Main Transformer T1

Supplies power to output circuit, power
control board PC1, safety control board
PC2, and fan motor FM.

3

Fan Motor FM

Provides cooling of internal components.

4

Integrated Rectifier SR1

Changes AC output from T1 to full-wave
rectified DC.

5

Power Control Board PC1

Supplies and regulates cutting current
to torch. Also provides some timing and
control functions.

6

Safety Control Board PC2

Provides timing and control functions,
monitors safety interlocks and provides
isolation from power circuitry. Also
contains power, ready and trouble LEDs.

7

Output Control R6

Selects cutting output level.

8

Thermostat TP1

If unit overheats, TP1 opens stopping
cutting output. TP1 is located inside T1.

9

Power-Up Delay Relay CR6,
Input Resistor R2

During power-up (2-3 seconds), R2 limits
inrush current to T1. CR6 shorts out R2
after power up delay and keeps R2
shorted out while the unit is operating.

10

Contactor Control Relay CR7

Connects main transformer T1 secondary
output power to integrated rectifier SR1.

11

Air Filter/Regulator

Filters and regulates pressure of input air
supply.

12

Air Valve GS1

Allows airflow for pilot arc, cutting and
postflow.

13

Air Pressure Switch S3

Provides signal to PC2 to shut down unit
if air pressure is to low.

Output

Control

R6

Safety

Control Board

PC2

Air

Valve

GS1

Air Pressure

Switch

S3

Power-Up

Delay

Relay CR6

Contactor

Control

Relay CR7

Thermostat

TP1

Input Air Supply

70-120 psi

(4.8-8.3 bar)

9

Power

Switch S1

1

6

7

8

9

10

12

13

Air Filter/

Regulator

60 psi

(4.1bar)

11

7-98