Controls and indicators

6.0
BAR

5.0

4.0

PSI

80

70

5060

60

40

AMPS

80

25

V

AC

+

_

Current
(amps)
adjustment
knob

Mode switch

Indicator
LEDs

Pressure
gauge

Pressure
regulator

ON (I) / OFF (O)
switch (S1)

Green power ON LED
When illuminated, indicates that power is applied to the system and the power switch is ON ( I ).

Gas

pressure

LED

Yellow:

When flashing, indicates that the gas pressure is below 60 psig (4.1 bar) for cutting, or 40 psig
(2.8 bar) for gouging.

Green: When illuminated, indicates that there is acceptable gas pressure for torch operation.
Note: This LED should illuminate when the power is ON ( I ).

Yellow

torch cap

LED

When illuminated, indicates that the retaining cap is loose or not installed.
Note: Turn OFF (O) the power, correct this fault condition, then turn ON (I) the power to extinguish the
LED.

Yellow

temperature

LED

When illuminated, indicates that the power supply’s temperature is too hot.

Red

fault

LED

When illuminated, indicates that a fault condition exists, which prevents system operation.

Yellow

low line voltage

LED

When illuminated, indicates that line voltage is below 170 VAC or above 680 VAC. On CE units, it can
also indicate a missing phase.