Test 1 – voltage input, Powermax1250, Maintenance 3-22 – Hypertherm Powermax1250 Service Manual User Manual

Page 55: Service manual

Advertising
background image

MAINTENANCE

3-22

powermax1250

Service Manual

4

Test 1 – voltage input

• Check the line voltage to the top of the power switch (S1).

• Check the input voltage to the input diode bridge.

• The AC voltage between any 2 input wires should equal the line voltage.

• If there is proper voltage to the power switch and low voltage to the input diode, replace the power switch.

– For CE systems, check the voltage at the CE filter. If there is proper voltage to CE filter and low voltage

to the input diode, replace the CE filter.

• Check the output voltage of the input diode bridge.

• Output VDC = Line Voltage x 1.414 VDC

Note:

All values can be ±15%.

= Line voltage*

= Line voltage

= Line voltage*

Input diode bridge

Power switch (S1)

* Single phase

Line voltage x 1.414

Ground (PE)

L1

L2

L3

Standard unit

CE unit

L1

Black

Black (U)

L2

White

Blue (V)

L3

Red

Brown (W)

PE

Green

Green/Yellow

Advertising