Torch Installation

Turn OFF power.

Remove power cord from power receptacle.

1. Align the connector key-way on the torch lead with the connector receptacle on the power supply and

push in until the pins seat.

2. Before tightening, turn the connector securing ring 1/4 turn to the left to ensure that the securing ring

threads and the connector receptacle threads are aligned.

3. Turn the securing ring to the right to tighten.
4. Clean the top of the power supply and apply the new operation label over the existing label.

Receptacle

Securing ring

Operation label

(Part No. 110522)

Key-way

Note: If the receptacle is missing or damaged it should be replaced with a new receptacle.

Part Number

Description

028522

MAX42 receptacle

028523

MAX43 receptacle

029962

Powermax800 receptacle

128493

Powermax600 receptacle

129325

Powermax900 receptacle