Torch consumable configurations – Hypertherm RT60 Retrofit Torch User Manual

Page 31

Advertising
background image

OPERATION

4-4

RT60 / RT60M

Operator Manual

0

Torch Consumable Configurations

Mechanized, Shielded

Unshielded**

120930

120932

120928*

40A

120931

60A

120925

120926

120925

120926

Shield

Nozzle

Retaining Cap

Swirl Ring

Electrode

Ohmic Sensing

Retaining Cap

40A-60A

* Use an ohmic sensing cap when a

compatible torch height contoller is
installed.

** In CE countries, unshielded

consumables may only be used in
mechanized torch applications.

Maintain torch-to-work distance of
approximately 1/8 inch (3mm).

120928*

120930

220006

120928

40A

220007

60A

Shield

Nozzle

Retaining Cap

Swirl Ring

Electrode

120928

220061

120979

120979