IDK MSD-804FD User Manual
Page 107
MSD-804FD Users Guide (Command Guide)
107
@STF
Set flash time (Command keys and DISPLAY POWER keys)
Command 
format 
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
Return value 
format 
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
Parameter
switch_1-9
: key type
0 = All keys, 1 to 5 = COMMAND A to E,
6 to 9 = DISPLAY1 POWER to DISPLAY4 POWER
flash_1-9
: Flash time
-1 = Flash during command execution, 0 = Not flash,
1 to 1000 = Flash for the specified time (range: 1 to 1000 seconds)
[Default]: If COMMANDs A to I: 0 (Not flash),
If DISPLAYn POWER: -1 (Flash during command execution)
Example
Send 
 
Receive 
@STF,4,5
 
@STF,4,5
COMMAND D flashes for 5 seconds after command 
execution starts. 
Terminated normally. 
Related info.
8.12.8 Flash time (Command keys and DISPLAY POWER keys)
@GTF
Get flash time (Command keys and DISPLAY POWER keys)
Command 
format 
@GTF, switch_1 (, switch_2・・・)
Return value 
format 
@GTF, switch_1, flash_1 (, switch_2, flash_2・・・)
Parameter
switch_1-9
: key type
0 = All keys, 1 to 5 = COMMAND A to E,
6 to 9 = DISPLAY1 POWER to DISPLAY4 POWER
flash_1-9
: Flash time
-1 = Flash during command execution, 0 = Not flash,
1 to 1000 = Flash for the specified time (range: 1 to 1000 seconds)
[Default]: If COMMANDs A to I: 0 (Not flash),
If DISPLAYn POWER: -1 (Flash during command execution)
Example
Send 
Receive 
@GTF,9
@GTF,9,-1
Get flash time of DISPLAY4 POWER. 
Flashes during command execution. 
Related info.
8.12.8 Flash time (Command keys and DISPLAY POWER keys)