MSD-804FD Users Guide (Command Guide)

70

3.3.10 EDID

@SED Set

EDID

Command format @SED, ch_1, edid_1 (, ch_2, edid_2・・・)

Return value
format

@SED, ch_1, edid_1 (, ch_2, edid_2・・・)

Parameter

ch_1-8

: Input channel

0 = All inputs, 1 = IN1 to 5 = IN5

edid_1-5

: EDID data

0 = Built-in EDID [Default],

1 to 4 = EDID loaded from display device connected to OUTA*

1

5 to 8 = EDID loaded from display device connected to OUTB

101 to 108 = COPY DATA 1 to COPY DATA 8

*2

*1

OUT1B to OUT4B can be set only if Cat5e/Cat6 output option is installed.

*2

EDID data have to be loaded beforehand in @RME Copy EDID (P. 76).

Example Send


Receive

@SED,2,3


@SED,2,3

Set the EDID loaded from the display device that is
connected to OUT3A for IN2.
Terminated normally.

Related info.

8.9.1 EDID setting

@GED Get

EDID

Command format @GED

Return value
format

@GED, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8

Parameter

in_1

, in_2, in_3, in_4, in_5 : EDID data of each input channel

0 = Built-in EDID [Default],

1 to 4 = EDID loaded from display device connected to HDMI output
connector

5 to 8 = EDID loaded from display device connected to OUTB*

101 to 108 = COPY DATA 1 to COPY DATA 8

*2

*

OUT1B to OUT4B can be set only if Cat5e/Cat6 output option is installed.

Example Send

Receive

@GED

@GED,0,0,0,3,0,0,
0,0

Get EDID data.
IN4: EDID loaded from display device
connected to OUT3; other inputs: built-in
EDID

Related info.

8.9.1 EDID setting