Assembly, Operation – Desa BTU/HR User Manual

Page 5

Advertising
background image

www.desatech.com

113282-01C

5

ASSEMBLY

(FOR 110/115/155/165/200 MODELS
ONLY)

These models are furnished with wheels and a
handle. Some models are furnished with a second
handle also. Wheels, handle(s), and the mounting
hardware are found in the shipping carton.

Tools Needed
• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support frame. Install

wheel spacers if provided. Install wheels on axle.
IMPORTANT:

When installing wheels, point

extended hub of wheels toward wheel support
frame (see Figure 6).

2. Place cap nuts on axle ends. Gently tap with

hammer to secure.

3. Place heater on wheel support frame. Line up

holes on fuel tank flange with holes on wheel
support frame.

4. Place handle(s) on top of fuel tank flange. In-

sert screws through handle(s), fuel tank flange,
and wheel support frame. Attach nut finger
tight after each screw is inserted.

5. After all screws are inserted, tighten nuts

firmly.

Figure 6 - Wheel and Handle Assembly,

110/115/155/165/200 Models Only

Wheel Support
Frame

Fuel
Tank
Flange

Cap Nut

Wheel

Nut

Axle

Extended
Hub

Air
Inlet

Handle

Hot Air
Outlet

Screw

OPERATION

IMPORTANT: Review and under-
stand the warnings in the

Safety

Information section, page 2.
They are needed to safely oper-
ate this heater. Follow all local
ordinances and codes when
using this heater.

TO START HEATER

1. Follow all ventilation and safety information.
2. Locate heater to provide maximum circulation

of the heated air. Follow all location require-
ments noted in Safety Information, page 2.

3. Fill fuel tank with kerosene, #1#2 diesel/fuel

oil, JET A or JP-8 fuel.

4. Attach fuel cap.
5. For thermostat models, turn thermostat knob

clockwise to the high position.

6. Plug heater’s power cord into approved,

grounded, three-wire extension cord. Extension
cord must be at least six feet (1.8 meters) long.
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG
(0.75 mm

2

) rated cord

11 to 100 feet (3.3 to 30.5 meters) long, use
16 AWG (1.0 mm

2

) rated cord

101 to 200 feet (30.8 to 61 meters) long, use
14 AWG (1.5 mm

2

) rated cord

7. Plug extension cord into standard 120 volt/60

hertz, 3-prong grounded outlet.
Note:

For heater without ON/OFF switch, ig-

nitor will preheat for five seconds, then heater
will start.
Note:

For heater with ON/OFF switch, push

switch to ON(|) position and heater should start
in 5 seconds. If heater does not start, see
Troubleshooting, page 7.

8. For thermostat models, adjust thermostat knob

to the desired setting. Note: A cold heater may
affect the thermostat setting. This thermostat
is a general-heating control. It is not intended
for precise temperature control. Adjust thermo-
stat until heater cycles at the desired setting.

TO STOP HEATER

Without ON/OFF Switch
Unplug extension cord from outlet.

With ON/OFF Switch
Push ON/OFF switch to OFF (O) position. Un-
plug heater when not in use.

Wheel Spacer
(If Provided)

Cord Cleat with Bolts
and Nuts (If Provided -
Set of Two for Right or
Left Side)

Advertising