Preventative maintenance schedule, Troubleshooting, Warning: high voltage – Desa BTU/HR User Manual

Page 7

Advertising
background image

www.desatech.com

113282-01C

7

PREVENTATIVE MAINTENANCE SCHEDULE

WARNING: Never service heater while it is plugged in, operating,

or hot. Severe burns and electrical shock can occur.

How To

See Storing, Transporting, or
Shipping,
page 6

See Air Output, Air Intake, and
Lint Filters
, page 9

See Air Output, Air Intake, and
Lint Filters
, page 9

See Fuel Filter, page 10

See Fan, page 9

Item

Fuel tank

Air output and lint filters

Air intake filter

Fuel filter

Ignitor

Fan blades

Motor

How Often

Flush every 150-200 hours of operation
or as needed

Replace every 500 hours of operation or
once a year

Wash and dry with soap and water every
500 hours of operation or as needed

Clean twice a heating season or as needed

No maintenance required

Clean every season or as needed

Not required/permanently lubricated

TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, operating,

or hot. Severe burns and electrical shock can occur.

POSSIBLE CAUSE

1. No power to heater

2. ON/OFF switch not in the

ON(|) position

3. If equipped, thermostat setting

is too low

4. Bad electrical connection be-

tween motor and ignition con-
trol assembly or ignition con-
trol assembly and power cord

5. Binding pump rotor

6. Defective ignition control as-

sembly

7. Defective motor
8. Blown fuse or ignitor control

assembly

REMEDY

1. Check circuit breaker in elec-

trical panel

2. Verify the ON/OFF switch is in

ON (|) position and light is on

3. Turn thermostat knob to a

higher setting

4. Check all electrical connec-

tions. See Wiring Diagrams,
page 16

5. If fan does not turn freely, see

Pump Rotor, page 14

6 Replace ignition control as-

sembly

7. Replace motor
8. See Ignition Control Assem-

bly, page 15

FAULT CONDITION

Motor does not start five sec-
onds after heater is plugged in

WARNING: High voltage!

Advertising