Service procedures – Desa BTU/HR User Manual

Page 9

Advertising
background image

www.desatech.com

113282-01C

9

SERVICE PROCEDURES

WARNING: To avoid risk of

burn and electrical shock, never
attempt to service heater while it
is plugged in, operating, or hot.

UPPER SHELL REMOVAL

1. Remove screws along each side of heater using

5/16" nut-driver. These screws attach upper and
lower shells together. See Figure 10 or 11.

2. Lift upper shell off.
3. Remove fan guard.

Upper Shell

Fan Guard

Figure 10 - Upper Shell Removal,

40/50/55/60/70 Models Only

Figure 11 - Upper Shell Removal,

110/115/155/165/200 Models Only

Fan
Guard

Upper Shell

Screw

Screw

FAN

IMPORTANT:

Remove fan from motor shaft be-

fore removing motor from heater. The weight of
the motor resting on the fan could damage the fan
pitch (see Figure 12).
1. Remove upper shell (see Figure 10 or 11).
2. Use 1/8" allen wrench to loosen setscrew

which holds fan to motor shaft.

3. Slip fan off motor shaft.

Motor Shaft

Setscrew

Figure 12 - Fan, Motor Shaft, and

Setscrew Location

Motor
Shaft

Fan

Setscrew

Figure 13 - Fan Cross Section

Fan

Flush

Motor

4. Clean fan using a soft cloth moistened with

kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan hub

flush with end of motor shaft (see Figure 13).

7. Place setscrew on flat of shaft. Tighten setscrew

firmly (40-50 inch-pounds/4.5-5.6 n-m).

8. Replace fan guard and upper shell.

AIR OUTPUT, AIR INTAKE AND LINT
FILTERS

1. Remove upper shell (see Figure 10 or 11).
2. Remove filter end cover screws using 5/16" nut-

driver (see Figure 14 or Figure 15, page 10).

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see Preven-

tative Maintenance Schedule, page 7).

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output Filter

Figure 14 - Air Output, Air Intake, and

Lint Filters, 40/50/55/60/70 Models Only