Infloor Thermostatic regulating unit 31093-31094 User Manual

Page 4

Advertising
background image

∆p (m w.g.)

0

1

2

0,5

0

1,5

1

2

3

4

5

6

7

8

G (m

3

/h)

(kPa)

0

10

20

30

40

50

60

70

80

6

5
4

3
2
1

Min

1

2

3

4

5

6

7

Max

20

25

30

35

40

45

50

55

58

Position

Temp. (°C)

Temperature setting

The temperature is set to the desired temperature by using
the graduated adjustment knob fitted on the three-way
thermostatic valve.

Reference: T

boiler

= 70°C

Locking the setting

Set the knob on the desired
number, remove the screw on
the top, pull the knob off and
push it back on so that the
groove on the inside fits over
the ridge on the knob holder.

By-pass flow curves

Differential by-pass

The differential by-pass valve is used to control the head in
the secondary circuit. When the differential pressure set for
the valve is reached, the valve opens and allows fluid to pass
between the flow and return of the circuit, limiting the
differential pressure at the value set.
If the individual circuits to panels are shut-off by automatic
two way on/off or modulating valves, the valve prevents
excessive fluid velocities and the pump from overheating.

MIN

MAX

7

1

2

3

Cartridge replacement

The internal cartridge containing all the regulation components
can be inspected and replaced if necessary without the need
to remove the valve from the piping.

1) Close the hot and cold inlet shut-off valves

2) Remove the internal cartridge for inspection or replacement

by turning the nut as shown.

3) Replacement cartridges come complete with adjustment

knobs.

4) Open the shut-off valves again and set the mixing valve at

the temperature desired.

Setting positions