Infloor Thermostat 29060 User Manual

Infloor Radiators

Advertising
background image

29060 PROGRAMMABLE THERMOSTAT

USER’S GUIDE

LOCATION FOR INSTALLATION

INSTALLATION

1. Open the top housing as shown in Figure 1 and 2 with a screw

driver:

Figure 1

Figure 2

2. Be careful not to touch or move the slide switches on the front and

the back cover. If the switches are moved from their original position,

see NOTE ON INSTALLING THE FRONT LCD COVER on page 3.

USER SETTING

Press SET button for 6 seconds to enter the user setting mode,

and set the flashing indication on LCD:

1. C/F selection: Press. +/- to choose F/C setting. Then press OK to

enter 24H/12H setting.

2. 24H/12H selection: Press. +/- to choose 24H/12H setting. Then

press OK to enter DATE setting.

3. DATE: Press. +/- to choose YEAR. Then press OK to enter Month

setting.

4. MONTH: Press +/- to choose MONTH. Then press OK to enter DAY

setting.

5. DAY: Press +/- to choose DAY. Then press OK to enter CLOCK

setting.

6. CLOCK: Press +/- and OK to adjust current HOUR and MINUTE.

Then press OK to enter DIFFERENTIAL setting.

7. DIFFERENTIAL:

Press +/- to choose desired switching differential(1

or 2). Then press OK to enter FIL TER setting.

8. FIL TER: Press +/- to select filter hours from 100-hour to 9900-hour.

Note: for fan coil system, replacing the filter after using for certain

period of time in order to maintain the system performance. When

this function is activated, LCD will display “Reminder” signal on main

screen when the filter timer is expired. This function is not effective

for the system without FAN.

9. Press OK to return to main screen and run the settings.

Note: During this user setting mode, if no key is pressed for 30

seconds, thermostat will take the latest setting and start to run the

setting.

Look for a location, which

has a constant temperature

in the house and it is not

near the door entry or air

condition outlet (see

example on Figure 1).

WIRING DIAGRAM:

AC IN

L

AC IN

N

S

S

HEA
T

29060 for Radiant Floor Heating

NC

Floor Sensor

NO

COM

L

N

24VAC

PROGRAMMING THE THERMOSTAT

Note: During the program setting mode, the thermostat will return to

normal operating mode if no key is pressed for 30 secs.

KEY PAD DESCRIPTIONS

1. SET key: Use to enter program mode/view mode plus other

functions.

2. +/- key: + key increase or skip to next step. - key decrease or

return to previous step.

3. OK key: Press to enter setting or return to run the program.

4. RESET key: Press to reset the settings to factory default.

5. Manual Key: Override function control key.

Note: Override function is disabled if system switch

is set to OFF.

PROGRAM REVIEW

Note: Do not put system switch to OFF position.

1. Press SET .

2. Press OK to review each Temperature/Time Setting (Program)

Note: To exit program review mode, press SET key twice and then

press OK)

C. PROGRAM SETTING:

Note: Do not put system switch to OFF position. (For model with

system switch)

29060 Thermostat has 7-Day Programs with 6

Programs/day:

To set each daily program for all 7 days

1. Press SET to enter program setting, which starts with Mo-MORN

(Monday-Morning).

2. Press +/- to adjust 1st Temperature setting (P 1 Temperature)

3. Press OK to select Mo-Morn Time setting ( P 1 Time)

4. Press +/- to adjust Time setting

5. Follow procedures above to finish Temperature/Time setting for

the rest of program period for all 7 days.

6. When finished all program setting, press SET twice and then

press OK to start running the program.

Advertising