Fabrication of IPS Empress

®

CAD Restorations

– V

eneers / Cr

owns – stained / glazed

After staining, the stain and characterization firing is conducted in a
compatible ceramic furnace (e.g. Programat CS2). The following points
should be observed when placing the restoration in the furnace and setting
the firing parameters:

– Place veneers as well as anterior and posterior crowns on metal pins and

position them on the honey-comb firing tray.

– To better secure the restoration on the metal pins (particularly with

veneers), a small amount of IPS Object Fix Putty / Flow may also be used.

Firing parameters for the stain and characterization firing

(note the temperature control)

IPS Empress CAD with
IPS Empress Universal

B

°C / °F

S

min.

t

°C/min. / °F/min.

T

°C / °F

H

min.

V

1

°C / °F

V

2

°C / °F

Stain and glaze firing

403

6:00

100

790

01:00

B = Stand-by temperature °C / °F

S = Closing time/min.

t = Temperature increase rate °C/min. / °F/min.

T = Firing temperature °C / °F

H= Holding time/min.

V

1

= Vacuum-on temperature °C / °F

V

2

= Vacuum-off temperature °C / °F

The objects are placed on the honey-comb firing tray and the firing pro-

gram is started.

Optional

Shade check

To check the tooth shade after the first stain and characterization firing,
proceed as follows:
– Wet the inner aspects of the restoration with IPS Empress Universal Glaze

and Stain Liquid using a brush.

– Place the restoration on the individual control die, wet the surface and

check the tooth shade, as well as the individualized effects.

– If required, perform the necessary adjustments and fire the restoration

again using the same firing parameters.

Shade check. If necessary, the shade intensity can be increased by