Screw the Ti base onto a model analog. Mark the relative position to the structure with
a waterproof pen.
The instructions of the implant manufacturer must be observed. Carefully blast the
bonding surface with max. 50 µm and 1-2 bar (15-29 psi) pressure.
The instructions of the implant manufacturer must be observed.
Protect the emergence profile and the screw channel, e.g. by means of silicone
(Virtual Extra Light Body Fast Set).
Remove silicone and subsequently clean in an ultrasonic bath or with the steam jet.
Apply Monobond Plus on the cleaned bonding surface and allow to react for 60 s.
After the reaction time, dry the remaining residue with water- and oil-free air.
Seal the screw channel with a foam pellet or wax.